WWF Hong Kong
Environmental Team for
EP-598/2022 – Mai Po Nature Reserve Infrastructure Upgrade Project
Final EM&A Report
.
13
2.4.2 The monitoring data were managed by the ET’s in-house data recording and system. The
Laboratory, responsible for the analysis, adhered to QA/QC requirements as outlined under
the HOKLAS scheme.
2.4.3 In-situ monitoring data measured by the equipment were recorded by both field operators
and the equipment itself. Laboratory analysis results were directly issued by the designated
laboratory. All data were subsequently entered into a computerized database, appropriately
maintained by the ET. Cross-checking of results was conducted by other personnel.
2.4.4 In addition to the water quality parameters, other relevant data have also been measured and
recorded in field logs, including coordinates of the sampling stations, the location of
construction works at the time of sampling, sampling depth, weather conditions, special
phenomena and work activities undertaken around the monitoring and works area that may
influence the monitoring results, etc.
2.4.5 Throughout the monitoring period until August 2023, no significant change was observed in
the trend line of in-situ data measured for each water monitoring at designated monitoring
locations.
2.4.6 With the implementation of the measures recommended in the approved EM&A Manual, no
project-related exceedance of water quality monitoring was identified.
2.4.7 The above QA/QC results demonstrate that the equipment, lab analysis, field personnel, and
methodology for the EM&A monitoring are fit for their intended purpose and can provide data
of acceptable quality and reliability, as per the requirements outlined in the EM&A Manual.
The QA/QC information assures that any exceedances or non-compliances detected are valid
and not due to monitoring deficiencies.
Detection limits
2.4.8 DO and Temperature Measuring Equipment capable of measuring DO in the range of 0 to 20
mg/L and 0 to 200% saturation; and temperate of 0 to45 C, which shall be checked, calibrated.
2.4.9 Portable salinometer capable of measuring salinity in the range of 0-40 mg/l shall be provided
for measuring salinity of the water and certified before use by a HOKLAS laboratory.
2.4.10 Turbidity Measurement Equipment capable of measuring turbidity between 0-1000 NTU and
certified before use by a HOKLAS laboratory.
2.4.11 A high density 1L capacity polythene bottle shall be used to collect a water sample from just
below the water surface for SS measurements while water sample for O&G measurement shall
be collected in glass bottles and preserved by addition of H
2
SO
4
. At least two replicate samples